# 1SDA066984R1 – ABB – KIT CONNECTOR for Tmax XT
KIT x CONNECTION Ext Ne XT2-XT4 F/P
KIT CONNECTORS FOR EXTERNAL NEUTRAL FOR EKIP LSI - EKIP LSIG FOR FIXED-PLUG-IN C.BREAKER XT2-XT4.
# 1SDA067415R1-XT1N – ABB – XT1N 160 TMD 50-500 3p F F
CIRCUIT BREAKER TMAX XT1N 160 FIXED THREE-POLE
WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 50-500 A
36 kA
# 2CDS213001R0204 – ABB – SH203-C20
Compact Home SH200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C),
configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 40 A). All MCBs of the product range SH200 comply with IEC/EN 60898-1, allowing the use for residential applications.
# 2CDS213001R0324 – ABB – SH203-C32
Compact Home SH200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C),
configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 40 A). All MCBs of the product range SH200 comply with IEC/EN 60898-1, allowing the use for residential applications.
# 2CDS213001R0404 – ABB – SH203-C40
Compact Home SH200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C),
configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 40 A). All MCBs of the product range SH200 comply with IEC/EN 60898-1, allowing the use for residential applications.
#1SAZ721201R1043TF42-10 ABB
1SAZ721201R1043TF42-10 ABB
Three-phase string inverter, 10000Wac, 2 MPPT, RS485, IP65
for more information please call us at ( sales@ofuk-almajd-automation.com)
#1SBL177001R1310 -ABB – Magnet contactor, AC switch
AF16-30-10-13
AF16 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.#1SBL237001R1300- ABB
AF26-30-00-13
AF26-30-00-13 100-250V50/60HZ-DC Contactor
AF26 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.#1SDA051369R1 – ABB
AUX T1...T6 3Q 1SY
3 CHANGEOVER CONTACT OPEN-CLOSED + 1 CHANGEOVER FOR TRIPPED INDICATION T1-T2-T3-T4-T5-T6#1SDA054437R1 – ABB – CIRCUIT BREAKER TMAX T5N 400
T5N 400 TMA 400-4000 3p F F
C.BREAKER TMAX T5N 400 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 400 I3=2000...4000 A#1SDA054896R1-ABB
1SDA054896R1-ABB
ABB MOTOR OPERATOR FOR T4 SACE TMAX T CIRCUIT BREAKERS
KIT CONNECTORS FOR EXTERNAL NEUTRAL FOR EKIP LSI – EKIP LSIG FOR FIXED-PLUG-IN C.BREAKER XT2-XT4.